    UL Certified Fire-Rated Steel Door Frame Profiles

    Fire-rated steel door frame profiles are specialized life-safety structural hollow metal casings engineered to contain fire, toxic smoke, and extreme thermal radiation in commercial stairwells, hospital exit corridors, and industrial fire barrier walls. Precision roll formed from 1.5 mm to 2.0 mm hot-dip galvanized steel, our fire-rated profiles incorporate continuous intumescent seal grooves, thermal barrier rebates, and heavy-gauge ceramic-insulated reinforcement channels. Certified to UL 10C, NFPA 252, and BS 476 for 60, 90, and 120-minute fire endurance ratings, these door casings guarantee mechanical integrity under intense furnace heat and high-pressure firefighter hose-stream tests.

    About Certified Fire-Rated Steel Door Frame & Jamb Systems

    In modern high-occupancy commercial complexes, industrial plants, and healthcare infrastructure, passive fire protection systems depend on certified fire door assemblies to prevent horizontal and vertical fire spread. During a severe structural fire, internal temperatures exceed 1,000°C (1,800°F), generating violent thermal expansion forces that warp, twist, and pull standard door frames away from wall openings, creating fatal gaps through which lethal smoke and flames rush. Fire-rated steel door frame profiles are metallurgically and structurally engineered to maintain their dimensional geometry and structural anchoring under extreme thermal expansion gradients.

    Manufactured on precision roll forming lines from heavy galvanized steel, our profiles feature integral extruded rebates and recessed gasket channels designed to house high-expansion intumescent graphite fire seals. When exposed to heat above 150°C, these intumescent strips rapidly expand up to 25 times their original volume, forming a continuous foamed carbon char barrier that hermetically seals all perimeter door clearances against hot toxic smoke and lethal combustible gases. Corner joints feature full-depth continuous arc-welded miters reinforced with heavy internal corner gussets to prevent frame racking.

    Tested and labeled by Underwriters Laboratories (UL 10B / UL 10C Positive Pressure) and Warringtonfire (BS 476 Part 22 / EN 1634-1), our fire door frames withstand mandatory 30-psi hose-stream shock tests immediately following 2-hour furnace exposures without structural breach. Supplied with heavy-duty masonry anchors or UL-listed drywall compression clamps, our profiles provide certified life-safety compliance.

    Applications

    • Hospital Emergency Stairwell 120-Minute Fire Door Frame

      In hospital emergency stairwell 120-minute fire door frame, uL-certified 2-hour fire-rated galvanized steel door frame profiles installed with intumescent smoke seals in a hospital evacuation stairwell. Engineered with precision miter joints, heavy reinforcement plates, and robust interlocking slats, these certified door assemblies resist forced entry and wind suction.

    • Commercial High-Rise Fire Separation Wall Casing

      In commercial high-rise fire separation wall casing, continuous roll formed 1.5mm galvanized steel fire door jambs anchored into 2-hour fire-rated drywall partition walls of a commercial skyscraper. These heavy-duty roll-formed steel jambs and shutter curtains provide certified fire containment and perimeter security, ensuring dependable building compartmentalization.

    • Industrial Chemical Plant Explosion & Fire Barrier Frame

      In industrial chemical plant explosion & fire barrier frame, heavy-duty 2.0mm steel fire-rated door casings anchored with expansion bolts into reinforced concrete blast and fire containment walls. Manufactured from heavy-gauge galvanized steel, these architectural door profiles deliver tight air-seal closure, high impact resistance, and compliant life-safety performance.

    • Hotel Guest Room Corridor 60-Minute Smoke & Fire Frame

      In hotel guest room corridor 60-minute smoke & fire frame, architectural fire-rated door jamb profiles with recessed intumescent smoke gaskets installed along a luxury hotel corridor. Engineered with precision miter joints, heavy reinforcement plates, and robust interlocking slats, these certified door assemblies resist forced entry and wind suction.

    • Underground Metro Station Evacuation Tunnel Fire Jamb

      In underground metro station evacuation tunnel fire jamb, heavy hot-dip galvanized fire-rated steel door frames with grout-filled masonry anchors installed in an underground subway tunnel. These heavy-duty roll-formed steel jambs and shutter curtains provide certified fire containment and perimeter security, ensuring dependable building compartmentalization.

    Technical Overview

    ParameterInformation
    Fire Endurance Ratings60 Minutes (1 Hour), 90 Minutes (1.5 Hours), 120 Minutes (2 Hours), 180 Minutes (3 Hours)
    Certification StandardsUL 10C / UL 10B (Positive Pressure), NFPA 252, BS 476-22, EN 1634-1, CAN/ULC S104
    Material Thickness Range1.5 mm to 2.0 mm (16 Gauge to 14 Gauge heavy-duty fire-rated steel stock)
    Steel Substrate MaterialHot-Dip Galvanized Steel DX51D+Z (Z140–Z275), ASTM A653 Commercial Forming Steel
    Jamb Depth Dimensions4-3/4" (121 mm), 5-3/4" (146 mm), 6-3/4" (171 mm), 8-3/4" (222 mm) Standard Wall Depths
    Intumescent Seal GroovesRecessed 10x4 mm or 15x4 mm Integral Channel for High-Expansion Graphite Seals
    Corner ConstructionContinuous Full-Depth Arc-Welded Miter Joints with Heavy Internal Stiffener Brackets
    Hinge & Lock Reinforcements4.5 mm (7 Gauge) Steel Hinge Plates & Heavy-Gauge Boxed Strike Plate Housings
    Wall Anchoring MechanismsUL-Listed Masonry Wire Anchors, T-Strap Grout Anchors, Drywall Stud Compression Anchors
    Hose-Stream Test ComplianceWithstands 30–45 psi High-Pressure Water Stream Impact Following Furnace Burn

    FAQ

    What fire endurance ratings are available for roll formed steel door frame profiles?

    Our profiles are tested and certified for 60-minute, 90-minute, 120-minute (2-hour), and up to 180-minute (3-hour) fire ratings in accordance with UL 10C, NFPA 252, and BS 476-22 standards.

    How does positive pressure fire testing (UL 10C) affect door frame design?

    Positive pressure testing mimics real fire dynamics where high pressure pushes hot gases outward above the neutral pressure plane; frames must incorporate intumescent seals and rigid stops to prevent hot gas leakage.

    What role do intumescent seals play inside fire-rated door jamb grooves?

    When heated above 150°C, intumescent graphite compounds expand massively into a solid thermal insulating char, sealing the 3 mm door perimeter gap against smoke, flames, and toxic combustion gases.

    Can fire-rated steel door frames be installed into drywall stud partition walls?

    Yes, UL-listed drywall slip-on frames with heavy-duty internal steel compression anchors are certified for 90-minute and 120-minute fire barriers in gypsum drywall partition assemblies.

    What is the mandatory hose-stream test requirement for fire door frames?

    Immediately following the 1- to 3-hour fire furnace burn, the glowing red-hot door assembly is blasted with high-pressure water from a firefighter hose stream (30 psi); the frame must maintain structural integrity without separating from the wall.

    What steel gauge is required for a 120-minute UL-labeled fire door casing?

    A minimum of 1.5 mm (16 Gauge) galvanized or cold-rolled steel is required for 90-minute and 120-minute ratings, with 2.0 mm (14 Gauge) specified for heavy 180-minute industrial fire barrier frames.

    How are fire certification labels applied to manufactured door frames?

    Each certified frame receives a permanently embossed metal UL or WHI certification label riveted to the hinge jamb, recording the manufacturer, hourly fire rating, and applicable positive pressure standards.