Global B2B Roll Forming Sourcing Platform | Free RFQ Response within 24h


JIS G 3350 specifies light gauge steel channel sections (C-channels) used in building construction, equipment framing, and general structural applications in Japan. Unlike material standards (JIS G 3302 for galvanized sheet) that define feedstock properties, JIS G 3350 defines the finished channel product: cross-section geometry, dimensional tolerances, material grade, and mechanical property requirements of the completed section after roll forming or press braking.
The standard covers channels formed from hot-rolled or cold-rolled steel sheet and strip, including galvanized (JIS G 3302 feedstock) and uncoated material. Channel sizes are designated by height (web depth), flange width, flange thickness, and web thickness, using a naming convention that identifies the section dimensions in millimeters. JIS G 3350 channels are produced primarily by roll forming in Japan, with some smaller sizes formed by press braking.
For roll forming manufacturers, JIS G 3350 serves as both the product specification (what to produce) and the quality standard (what to verify). The roll tool design, material selection, and inspection criteria all reference the dimensional tables and tolerance classes in this standard. Channel products may be ordered with additional requirements for hole patterns, slots, or miter cuts specified on engineering drawings separate from the base JIS G 3350 cross-section definition.
JIS G 3350 defines standard channel sizes organized by web height. Each size specifies web depth (H), flange width (B), flange thickness (t1), web thickness (t2), and inside flange radius (r).
| Designation | H (mm) | B (mm) | t1 (mm) | t2 (mm) | r (mm) | Mass (kg/m) |
|---|---|---|---|---|---|---|
| 50 × 25 | 50 | 25 | 2.3 | 3.2 | 3.5 | 2.37 |
| 75 × 40 | 75 | 40 | 3.2 | 4.5 | 5.0 | 5.30 |
| 100 × 50 | 100 | 50 | 3.2 | 4.5 | 5.0 | 6.18 |
| 125 × 65 | 125 | 65 | 4.5 | 6.0 | 6.0 | 10.1 |
| 150 × 75 | 150 | 75 | 4.5 | 6.5 | 7.0 | 12.5 |
| 200 × 80 | 200 | 80 | 5.0 | 7.0 | 8.0 | 16.2 |
| 250 × 90 | 250 | 90 | 6.0 | 8.0 | 9.0 | 22.0 |
| Designation | Area (cm²) | Ix (cm&sup4) | Wx (cm³) | Typical Application |
|---|---|---|---|---|
| 50 × 25 | 3.02 | 8.5 | 3.4 | Light equipment framing; cable support |
| 100 × 50 | 7.87 | 78.0 | 15.6 | General building; partition support |
| 125 × 65 | 12.9 | 188 | 30.1 | Medium structural; platform framing |
| 150 × 75 | 15.9 | 354 | 47.2 | Building frame; equipment support |
| 200 × 80 | 20.6 | 708 | 70.8 | Heavy framing; crane runway support |
| 250 × 90 | 28.0 | 1450 | 116 | Primary structural channel |
Section properties are calculated for the nominal dimensions. Actual roll-formed properties vary within JIS G 3350 tolerance bands, affecting structural design calculations per JIS building codes.
JIS G 3350 channels are manufactured from steel grades specified in the referenced material standards. The most common feedstock grades for roll forming production are listed below.
| Material Standard | Grade | Yield Min (MPa) | Application |
|---|---|---|---|
| JIS G 3302 | SGHC Z18–Z27 | 205 | General purpose galvanized channels |
| JIS G 3302 | SGH400 Z22–Z27 | 400 | Structural galvanized channels |
| JIS G 3302 | SGH440 Z27 | 440 | High-strength structural channels |
| JIS G 3131 | SPHC | 205 | Uncoated; painted after forming |
| JIS G 3141 | SPCC | 205 | Cold-rolled uncoated; precision channels |
| JIS G 3101 | SS400 (hot rolled) | 245 | Heavy channels; press-brake formed sizes |
| Channel Size | Feedstock Thickness | Recommended Grade | Notes |
|---|---|---|---|
| 50 × 25 to 75 × 40 | 2.3–3.2 mm | SGHC Z18 | Light gauge; single-pass thickness |
| 100 × 50 to 125 × 65 | 3.2–4.5 mm | SGH400 Z22 | Medium structural; standard building |
| 150 × 75 to 200 × 80 | 4.5–6.5 mm | SGH440 Z27 | Heavy structural; high load capacity |
| 250 × 90 | 6.0–8.0 mm | SGH490 Z27 | Maximum standard size; heavy gauge feedstock |
JIS G 3350 specifies permissible deviations on channel dimensions after forming. Tolerances apply to the finished roll-formed product, not the feedstock strip.
| Dimension | Tolerance (mm) | Measurement Method | Roll Forming Control |
|---|---|---|---|
| Web height (H) | ±2.0 | Calipers across flanges | Roll gap; final stand overbend |
| Flange width (B) | ±2.0 | Calipers per flange | Side roll position; flange forming stands |
| Flange thickness (t1) | ±0.5 | Micrometer on flange | Feedstock thickness; bend thinning |
| Web thickness (t2) | ±0.5 | Micrometer on web | Feedstock thickness (no bending on web) |
| Inside radius (r) | ±2.0 | Radius gauge | Roll contour design; bend ratio |
| Flange angle | ±2° | Angle gauge or square | Final stand overbend compensation |
| Twist | 1/200 per meter | Twist wire over 1 m | Leveler; symmetric roll pass design |
| Camber | 1/1000 per meter | String line over 3 m | Leveler; entry guide alignment |
| Ordered Length (mm) | Tolerance (mm) | Cutoff Method |
|---|---|---|
| ≤ 6000 | ±5 | Stop-to-cut or precision flying cutoff |
| 6000–12000 | ±8 | Flying cutoff with encoder control |
| > 12000 | ±10 | Special order; stop-to-cut preferred |
JIS G 3350 channels are produced on roll forming lines configured for C-channel geometry. The forming sequence progresses from flat strip through gradual bend stages to the final channel profile with specified flange width, web depth, and inside radius.
| Channel Size | Stands | Feedstock (mm) | Line Speed | Key Equipment |
|---|---|---|---|---|
| 50 × 25 | 10–12 | 2.3–3.2 | 15–25 m/min | Leveler; flying shear cutoff |
| 100 × 50 | 12–14 | 3.2–4.5 | 12–20 m/min | Leveler; flying shear; side rolls |
| 125 × 65 | 14–16 | 4.5–6.0 | 10–18 m/min | Heavy leveler; hydraulic cutoff |
| 150 × 75 | 14–16 | 4.5–6.5 | 8–15 m/min | Precision leveler; stop-to-cut option |
| 200 × 80 | 16–18 | 5.0–7.0 | 6–12 m/min | Heavy mill; hydraulic flying shear |
| 250 × 90 | 18–20 | 6.0–8.0 | 5–10 m/min | Heavy mill; stop-to-cut; crane stacking |
Developed strip width for JIS G 3350 channels equals the web depth plus twice the flange width minus twice the inside radius allowance (bend deduction per flange). Roll tool design uses the specific inside radius (r) from the standard tables to calculate accurate developed width and prevent flange height deviation at the final stand.
Symmetrical roll pass design produces balanced forming forces on upper and lower rolls, minimizing twist tendency in the finished channel. Asymmetric passes — where one flange forms before the other — are used on some lines to accommodate limited stand count, but require additional side rolls and careful overbend tuning to meet JIS G 3350 twist limits of 1/200 per meter.
| Channel | Formula Component | Value (mm) | Developed Width (mm) | Slit Coil Width Ordered |
|---|---|---|---|---|
| 100 × 50 | H + 2B − 2r + bend allowance | 100 + 100 − 10 + 8 | ~198 | 200 (rounded up) |
| 125 × 65 | H + 2B − 2r + bend allowance | 125 + 130 − 12 + 10 | ~253 | 255 (rounded up) |
| 150 × 75 | H + 2B − 2r + bend allowance | 150 + 150 − 14 + 12 | ~298 | 300 (rounded up) |
Slit coil width is ordered at or slightly above calculated developed width to allow edge trim if burr orientation is unfavorable. Entry guide rolls center the strip; excess width appears as symmetric edge margin in the entry guide, not as profile dimension error.
Production quality verification for JIS G 3350 channels follows a defined inspection sequence on first-article and periodic samples during production runs. Inspection frequency increases when changing feedstock coil grade or thickness, when restarting after a line stop exceeding 30 minutes, or when the customer quality plan specifies enhanced sampling rates for structural applications. Digital caliper readings are recorded on the production traveler accompanying each bundle of cut channel lengths shipped to the customer.
| Step | Inspection Item | Frequency | Acceptance | Tool |
|---|---|---|---|---|
| 1 | Web height H | First article + every 50 pcs | ±2.0 mm | Digital caliper |
| 2 | Flange width B | First article + every 50 pcs | ±2.0 mm | Digital caliper |
| 3 | Flange angle | First article + every 100 pcs | 90° ±2° | Angle gauge |
| 4 | Twist | First article + every 100 pcs | 1/200 per m | Twist wire |
| 5 | Camber | First article + every 100 pcs | 1/1000 per m | String line |
| 6 | Length | Every piece (inline) | Per order ±5–8 mm | Encoder / tape measure |
| 7 | Coating condition | First article per coil | No flaking; no excessive marking | Visual; bend test sample |
| 8 | Surface appearance | Continuous visual | No roll marks; no scoring | Visual under standard lighting |
JIS G 3350 channels serve as structural and non-structural framing elements across Japanese construction and industrial sectors.
| Application | Channel Size | Material | Environment | Notes |
|---|---|---|---|---|
| Building frame | 100 × 50 to 150 × 75 | SGH400 Z27 | Interior/exterior | Primary application; JIS building code |
| Equipment support | 75 × 40 to 125 × 65 | SGHC Z18 | Industrial indoor | Machine frames; conveyor support |
| Platform framing | 125 × 65 to 200 × 80 | SGH440 Z27 | Industrial | Walkway; maintenance platform |
| Cable tray support | 50 × 25 to 75 × 40 | SGHC Z18 | Indoor/outdoor | Light load; accessory channel |
| Crane runway | 200 × 80 to 250 × 90 | SGH490 Z27 | Industrial | Heavy load; structural calculation required |
| Solar panel frame | 100 × 50 to 125 × 65 | SGH440 Z27 | Outdoor | Mounting rail support structure |
| Partition wall stud | 50 × 25 to 75 × 40 | SGHC Z12 | Interior | Non-structural partition framing |
| Sign support | 75 × 40 to 100 × 50 | SGH400 Z22 | Outdoor | Wind load; moderate structural |
JIS G 3350 channels are distributed through Japanese steel service centers and building material suppliers with mill test certificates documenting material grade, coating mass, and dimensional inspection results. Roll forming manufacturers supply channels cut to length per order with inspection reports referencing JIS G 3350 tolerance compliance.
| Connection Type | Typical Channel Size | Fastener | Fabrication Note |
|---|---|---|---|
| Bolted frame joint | 100 × 50 to 150 × 75 | M12–M16 high-strength bolt | Drill or punch through web/flange after forming |
| Weld connection | 125 × 65 to 250 × 90 | Fillet weld 4–6 mm leg | Remove coating at weld zone; re-galvanize if exterior |
| Clip connection | 50 × 25 to 75 × 40 | Spring clip or screw | Non-structural partition framing |
| Slot and tab | 75 × 40 to 100 × 50 | Self-locking tab | Inline slot punch before cutoff on roll forming line |