    1. Definition and Scope

    JIS G 3350 specifies light gauge steel channel sections (C-channels) used in building construction, equipment framing, and general structural applications in Japan. Unlike material standards (JIS G 3302 for galvanized sheet) that define feedstock properties, JIS G 3350 defines the finished channel product: cross-section geometry, dimensional tolerances, material grade, and mechanical property requirements of the completed section after roll forming or press braking.

    The standard covers channels formed from hot-rolled or cold-rolled steel sheet and strip, including galvanized (JIS G 3302 feedstock) and uncoated material. Channel sizes are designated by height (web depth), flange width, flange thickness, and web thickness, using a naming convention that identifies the section dimensions in millimeters. JIS G 3350 channels are produced primarily by roll forming in Japan, with some smaller sizes formed by press braking.

    For roll forming manufacturers, JIS G 3350 serves as both the product specification (what to produce) and the quality standard (what to verify). The roll tool design, material selection, and inspection criteria all reference the dimensional tables and tolerance classes in this standard. Channel products may be ordered with additional requirements for hole patterns, slots, or miter cuts specified on engineering drawings separate from the base JIS G 3350 cross-section definition.

    2. Profile Types and Dimensions

    JIS G 3350 defines standard channel sizes organized by web height. Each size specifies web depth (H), flange width (B), flange thickness (t1), web thickness (t2), and inside flange radius (r).

    2.1 Standard Channel Sizes (Selected)

    DesignationH (mm)B (mm)t1 (mm)t2 (mm)r (mm)Mass (kg/m)
    50 × 2550252.33.23.52.37
    75 × 4075403.24.55.05.30
    100 × 50100503.24.55.06.18
    125 × 65125654.56.06.010.1
    150 × 75150754.56.57.012.5
    200 × 80200805.07.08.016.2
    250 × 90250906.08.09.022.0

    2.2 Section Property Reference

    DesignationArea (cm²)Ix (cm&sup4)Wx (cm³)Typical Application
    50 × 253.028.53.4Light equipment framing; cable support
    100 × 507.8778.015.6General building; partition support
    125 × 6512.918830.1Medium structural; platform framing
    150 × 7515.935447.2Building frame; equipment support
    200 × 8020.670870.8Heavy framing; crane runway support
    250 × 9028.01450116Primary structural channel

    Section properties are calculated for the nominal dimensions. Actual roll-formed properties vary within JIS G 3350 tolerance bands, affecting structural design calculations per JIS building codes.

    3. Material Specification

    JIS G 3350 channels are manufactured from steel grades specified in the referenced material standards. The most common feedstock grades for roll forming production are listed below.

    Material StandardGradeYield Min (MPa)Application
    JIS G 3302SGHC Z18–Z27205General purpose galvanized channels
    JIS G 3302SGH400 Z22–Z27400Structural galvanized channels
    JIS G 3302SGH440 Z27440High-strength structural channels
    JIS G 3131SPHC205Uncoated; painted after forming
    JIS G 3141SPCC205Cold-rolled uncoated; precision channels
    JIS G 3101SS400 (hot rolled)245Heavy channels; press-brake formed sizes

    3.1 Material Selection by Channel Size

    Channel SizeFeedstock ThicknessRecommended GradeNotes
    50 × 25 to 75 × 402.3–3.2 mmSGHC Z18Light gauge; single-pass thickness
    100 × 50 to 125 × 653.2–4.5 mmSGH400 Z22Medium structural; standard building
    150 × 75 to 200 × 804.5–6.5 mmSGH440 Z27Heavy structural; high load capacity
    250 × 906.0–8.0 mmSGH490 Z27Maximum standard size; heavy gauge feedstock

    4. Dimensional Tolerances

    JIS G 3350 specifies permissible deviations on channel dimensions after forming. Tolerances apply to the finished roll-formed product, not the feedstock strip.

    4.1 Cross-Section Dimension Tolerances

    DimensionTolerance (mm)Measurement MethodRoll Forming Control
    Web height (H)±2.0Calipers across flangesRoll gap; final stand overbend
    Flange width (B)±2.0Calipers per flangeSide roll position; flange forming stands
    Flange thickness (t1)±0.5Micrometer on flangeFeedstock thickness; bend thinning
    Web thickness (t2)±0.5Micrometer on webFeedstock thickness (no bending on web)
    Inside radius (r)±2.0Radius gaugeRoll contour design; bend ratio
    Flange angle±2°Angle gauge or squareFinal stand overbend compensation
    Twist1/200 per meterTwist wire over 1 mLeveler; symmetric roll pass design
    Camber1/1000 per meterString line over 3 mLeveler; entry guide alignment

    4.2 Length Tolerance

    Ordered Length (mm)Tolerance (mm)Cutoff Method
    ≤ 6000±5Stop-to-cut or precision flying cutoff
    6000–12000±8Flying cutoff with encoder control
    > 12000±10Special order; stop-to-cut preferred

    5. Roll Forming Production

    JIS G 3350 channels are produced on roll forming lines configured for C-channel geometry. The forming sequence progresses from flat strip through gradual bend stages to the final channel profile with specified flange width, web depth, and inside radius.

    5.1 Typical Roll Forming Line Configuration

    Channel SizeStandsFeedstock (mm)Line SpeedKey Equipment
    50 × 2510–122.3–3.215–25 m/minLeveler; flying shear cutoff
    100 × 5012–143.2–4.512–20 m/minLeveler; flying shear; side rolls
    125 × 6514–164.5–6.010–18 m/minHeavy leveler; hydraulic cutoff
    150 × 7514–164.5–6.58–15 m/minPrecision leveler; stop-to-cut option
    200 × 8016–185.0–7.06–12 m/minHeavy mill; hydraulic flying shear
    250 × 9018–206.0–8.05–10 m/minHeavy mill; stop-to-cut; crane stacking

    Developed strip width for JIS G 3350 channels equals the web depth plus twice the flange width minus twice the inside radius allowance (bend deduction per flange). Roll tool design uses the specific inside radius (r) from the standard tables to calculate accurate developed width and prevent flange height deviation at the final stand.

    Symmetrical roll pass design produces balanced forming forces on upper and lower rolls, minimizing twist tendency in the finished channel. Asymmetric passes — where one flange forms before the other — are used on some lines to accommodate limited stand count, but require additional side rolls and careful overbend tuning to meet JIS G 3350 twist limits of 1/200 per meter.

    5.2 Strip Width Calculation

    ChannelFormula ComponentValue (mm)Developed Width (mm)Slit Coil Width Ordered
    100 × 50H + 2B − 2r + bend allowance100 + 100 − 10 + 8~198200 (rounded up)
    125 × 65H + 2B − 2r + bend allowance125 + 130 − 12 + 10~253255 (rounded up)
    150 × 75H + 2B − 2r + bend allowance150 + 150 − 14 + 12~298300 (rounded up)

    Slit coil width is ordered at or slightly above calculated developed width to allow edge trim if burr orientation is unfavorable. Entry guide rolls center the strip; excess width appears as symmetric edge margin in the entry guide, not as profile dimension error.

    6. Quality Inspection

    Production quality verification for JIS G 3350 channels follows a defined inspection sequence on first-article and periodic samples during production runs. Inspection frequency increases when changing feedstock coil grade or thickness, when restarting after a line stop exceeding 30 minutes, or when the customer quality plan specifies enhanced sampling rates for structural applications. Digital caliper readings are recorded on the production traveler accompanying each bundle of cut channel lengths shipped to the customer.

    StepInspection ItemFrequencyAcceptanceTool
    1Web height HFirst article + every 50 pcs±2.0 mmDigital caliper
    2Flange width BFirst article + every 50 pcs±2.0 mmDigital caliper
    3Flange angleFirst article + every 100 pcs90° ±2°Angle gauge
    4TwistFirst article + every 100 pcs1/200 per mTwist wire
    5CamberFirst article + every 100 pcs1/1000 per mString line
    6LengthEvery piece (inline)Per order ±5–8 mmEncoder / tape measure
    7Coating conditionFirst article per coilNo flaking; no excessive markingVisual; bend test sample
    8Surface appearanceContinuous visualNo roll marks; no scoringVisual under standard lighting

    7. Roll Forming Applications

    JIS G 3350 channels serve as structural and non-structural framing elements across Japanese construction and industrial sectors.

    ApplicationChannel SizeMaterialEnvironmentNotes
    Building frame100 × 50 to 150 × 75SGH400 Z27Interior/exteriorPrimary application; JIS building code
    Equipment support75 × 40 to 125 × 65SGHC Z18Industrial indoorMachine frames; conveyor support
    Platform framing125 × 65 to 200 × 80SGH440 Z27IndustrialWalkway; maintenance platform
    Cable tray support50 × 25 to 75 × 40SGHC Z18Indoor/outdoorLight load; accessory channel
    Crane runway200 × 80 to 250 × 90SGH490 Z27IndustrialHeavy load; structural calculation required
    Solar panel frame100 × 50 to 125 × 65SGH440 Z27OutdoorMounting rail support structure
    Partition wall stud50 × 25 to 75 × 40SGHC Z12InteriorNon-structural partition framing
    Sign support75 × 40 to 100 × 50SGH400 Z22OutdoorWind load; moderate structural

    JIS G 3350 channels are distributed through Japanese steel service centers and building material suppliers with mill test certificates documenting material grade, coating mass, and dimensional inspection results. Roll forming manufacturers supply channels cut to length per order with inspection reports referencing JIS G 3350 tolerance compliance.

    7.1 Connection and Fabrication Details

    Connection TypeTypical Channel SizeFastenerFabrication Note
    Bolted frame joint100 × 50 to 150 × 75M12–M16 high-strength boltDrill or punch through web/flange after forming
    Weld connection125 × 65 to 250 × 90Fillet weld 4–6 mm legRemove coating at weld zone; re-galvanize if exterior
    Clip connection50 × 25 to 75 × 40Spring clip or screwNon-structural partition framing
    Slot and tab75 × 40 to 100 × 50Self-locking tabInline slot punch before cutoff on roll forming line

    References

    1. Japanese Industrial Standards Committee. "JIS G 3350:2021 — Light Gauge Steel Channels." jisc.go.jp
    2. Japanese Industrial Standards Committee. "JIS G 3302:2019 — Hot-Dip Zinc-Coated Steel Sheet and Strip." jisc.go.jp
    3. Japan Iron and Steel Federation. "Structural Use of Light Gauge Steel Channels." jisf.or.jp
    4. Building Center of Japan. "Light Gauge Steel Channel Application Guide." bcj.or.jp
    5. Fiellbach, K. "Roll Forming Handbook." CRC Press, 2019.
    6. Nippon Steel. "JIS G 3350 Channel Sections Product Catalog." nipponsteel.com
    7. Engel, B. "Roll Forming C-Channel Profiles: Tool Design and Tolerance Control." formtekgroup.com