Global B2B Roll Forming Sourcing Platform | Free RFQ Response within 24h


Chinese and English quotation files for the same effective-width tier do not always use identical speed wording. That is a documentation conflict, not proof that one number is wrong. Publish both bands when both appear in evidence, then lock the rating on the mutually confirmed technical proposal.
Do not average 8鈥?0 and 8鈥?2 into a fake 鈥?鈥?1鈥?band, and do not silently drop one language pack to make the encyclopedia look tidy.
| Source language | Speed wording |
|---|---|
| Chinese quotation reference | ~8鈥?0 m/min |
| English quotation reference | ~8鈥?2 m/min |
Same tier also cites forming power about 2脳11 kW and hydraulic about 5.5 kW in the Chinese reference. Control brands may differ across language packs (Panasonic / Delta / Mitsubishi cited; English may emphasize Delta) 鈥?do not freeze a single brand as universal truth.
Public industry guides often advertise wider forming bands such as about 8鈥?5 m/min or 10鈥?5 m/min depending on profile and cut method. Some high-speed ads claim about 15鈥?5 or even 20鈥?0 m/min class. Use those only as market context. They do not override the dual FAQ figures above, and they must not be published as ZTRFM鈥檚 locked rating for a named width.
The number on the signed technical proposal for that order 鈥?not a blended average of marketing pages.
Not necessarily. It can be quotation wording variance for the same tier. Verify with engineering rather than assuming a drive upgrade.
Not as a substitute for FAQ-backed ranges on these width packages.
Closed ~600 evidence in the main set uses Chinese ~8鈥?0 without inventing a second English band here. Keep widths labeled.
Final ratings follow the named technical proposal. Price and lead time are out of scope. CMS suggestion: draft + needs_verification.